herunterladen
![](https://oss-datasheet.aipcba.com/html/C0B40946BBEA0187BEBC3D5C63FA68BE/bg1.png)
Installation Instructions for the
ISSUE 1
MICRO SWITCH 40PC Series 1 psi Miniature
Signal Conditioned Pressure Sensor
PK 80036
MICRO SWITCH Sensing and Control
PERSONAL INJURY
• DO NOT USE these products as safety or
emergency stop devices, or in any other
application where failure of the product could
result in personal injury.
Failure to comply with these instructions could
result in death or serious injury.
GENERAL INFORMATION
40PC Series miniature pressure sensors are fully
compensated and amplified. The 0.5 to 4.5 V analog
output voltage signal is linearly proportional to input
pressure.
The miniature 6-pin DIP package mounts easily
on printed circuit boards. Pin 1 is clearly indicated
by the square corner. The 3 pins opposite the 3
active pins are inactive and may be clipped off if
desired.
SOLDERING/ASSEMBLY
Limit soldering to 315°C (600°F) maximum for 10
seconds maximum. Leads must be adequately
supported during any forming/shearing operation to
ensure that the leads are not stressed inside the
plastic case.
Clean appropriately in accordance with applicable
safety procedures
ELECTRICAL CONNECTION
L
GND
(2)
R
(3)
OUT
IN
+Vs
(1)
NOTES:
1. Square corner marks
pin 1 (Vs).
2. Input and output share
common ground.
3. 1 mmHg = 0.0193 psi.
CATALOG LISTINGS
40PC001B1A
40PC001B2A
40PC001B3A
SPECIFICATIONS
Pressure Range -50 to +50 mmHg
Overpressure 170 mmHg max.
Supply Voltage 5 VDC
Supply Current 10 mA max.
Output Source Current 0.5 mA max.
Output Sink Current 1.0 mA max.
Short Circuit Limit May be shorted
indefinitely
Operating Temperature -45 to +85°C (-49 to
+185°F)
Storage Temperature -45 to +85°C (-49 to
+185°F)
Media Compatibility Limited to those
media which will not
attack invar, copper,
silicon, stainless
steel, glass and
solder
Null (0 psig) 2.50 ± 0.05 VDC
Full Scale (+ 50mm Hg) 4.50 ± .12 VDC
Full Scale (- 50mm Hg) 0.50 VDC Typ.
Span 4.00 VDC Typ.
Sensitivity 40.0 mV/mmHg Typ.
Linearity (B.F.S.L.)* 0.80% Span, Max.
Hysteresis & Repeatability 0.15% Span, Typ.
*Best Fit Straight Line
CAUTION
ELECTROSTATIC
SENSITIVE
DEVICES
ESD SENSITIVITY:
CLASS I
DO NOT OPEN OR HANDLE
EXCEPT AT A
STATIC FREE WORKSTATION